This page explains how long the STICKER batteries last, how the device reports their level and what happens when they run low or you replace them.

Battery life​

STICKER runs 2+ years on 2× AA. The real battery life depends on the settings and on the radio conditions at the site. It gets shorter with:

  • A shorter report interval (interval-report, default 15 min). Every report wakes the device and transmits.
  • Poor coverage and frequent rejoins. Far from a gateway, each report needs a slower radio setting and many times more energy. A device without coverage keeps trying to join.
  • The Hall sensor variant. Its two Hall sensors draw current all the time.

How the battery level is reported​

The device measures the battery with every sensor reading, by default once per report. You find the value here:

  • Telemetry (the regular measurement report): voltage in volts. Use it to follow the battery over time.
  • Info uplink (a message with device information): battery in mV.
  • Network server: on request, a battery level from 1 (2.4 V or less) to 254 (3.6 V or more). 255 means unknown. ChirpStack, for example, shows it as the device battery.

Low battery​

When the voltage drops below the low-battery threshold (battery-level, default 2.4 V), the device sends an alarm report (a message about the alarm) and a telemetry report within about 10 s. While it is Connected, its LED adds a red flash every 3 s. The alarm is built in and needs no alarm rule. It clears when the voltage rises more than 0.3 V above the threshold (above 2.7 V by default), with a second alarm report. The threshold is configurable, see Alarms.

A separate check runs only at startup: below 1.8 V the device does not start, blinks red and switches itself off until you replace the batteries. See Startup and initialization.

Replacing the batteries​

With new batteries the device starts as usual and joins the network again. A LoRa P2P device keeps its pairing.

  • Kept: settings, network keys, Hall and input counter totals and sensor history. Only the most recent unsaved pulses and history records can be lost.
  • Set again: the clock, from the network after the join or with Sync time in Tools of HARDWARIO Manager. History records from before that then get their correct time.
  • Cleared: active alarms, without a clearing report (those that still apply are raised again), messages waiting to be sent and the PIR and accelerometer motion counts.

More detail is in History and counters.