Application Overview

CHESTER Push has push buttons on the enclosure. The application immediately sends data when any of the push buttons are pressed. For bulk orders, the number of buttons can be configured. An off-the-shelf configuration provides four push buttons on the left side. Alternatively, we can deliver a single push-button version (in the enclosure center). Also, upon a customer's request, we can customize the enclosure printing, and provide various text labels (or symbols) next to each of the push buttons.

The application can differentiate between a short press and a long press. In each message, there is an event distinguishing which of the push buttons triggered the sending. Every message also contains counters of each push button for short and long presses.

Each button is also equipped with an LED indicator so the operator can see that the press was recognized. Also, the beep sound is played from the integrated acoustic buzzer for audible confirmation of the push button press.

The CHESTER Push application integrates a CHESTER-Z-F extension module with a rechargeable Li-Ion battery and DC/DC power supply (input voltage range of 6 VDC to 26 VDC) that can charge the battery and provide a steady power supply for the application. The reported message also provides information about the external power presence, external DC line voltage, and battery voltage. With that extra information, CHESTER Push could also be used to monitor power outages.

CHESTER Push also reports temperature and device orientation (using the built-in accelerometer). All these values are provided in every message sent from the device.

LED Behaviour

The application signals push-button events on LEDs in two different ways and customers can specify which firmware variant better suits their needs.

  • Standard CHESTER Push implementation:

    The LED on the pressed push button is active for 2 seconds (green for short press, red for long press).

    tip

    This variant makes it suitable for low-power operation (months from the integrated Li-Ion battery).

  • Alternate CHESTER Push FM (stands for Flip Mode) implementation:

    The LED on the pressed push button flips (with red color) to the push button that has been pressed (the previous push button is switched off).

    caution

    This variant makes is not suitable for low-power operation as the constantly activated LED quickly discharges the battery.

Hardware Description

The catalog application CHESTER Push hardware consists of the following ordering codes:

  • CHESTER-M-CGLS - CHESTER mainboard
  • CHESTER-Z-F - Four push buttons (see Ordering Codes for more variants)
  • CHESTER-E2-LP - Enclosure with light pipe and SMA antenna pigtail

Enclosure Template

You can use a front cover template for your custom enclosure design.

Default Configuration

This is the default configuration (printed using the app config show command):

app config interval-report 1800
app config event-report-delay 1
app config event-report-rate 60
app config backup-report-connected false
app config backup-report-disconnected false

Specific Commands

info

You can easily explore the whole command tree structure - start with the help command.

Use this command to set report interval (in seconds):

app config interval-report <value>

Use this command to configure a short delay (in seconds) between the button or backup event and its reporting:

app config event-report-delay <value>

Use this command to limit the number of asynchronous button or backup event reports in a one-hour window:

app config event-report-rate <value>
tip

This feature helps to conserve power in the battery-operated device and optimizes the amount of transferred data. The regular (periodic) reports set by the parameter interval-report are not counted to this limit.

Use these commands to enable/disable reporting of the backup module power input connect/disconnect events:

app config backup-report-connected false
app config backup-report-disconnected false

Firmware

danger

When upgrading firmware from v1.x.x to version v2.0.0 and newer - it is necessary to backup configuration.

The latest firmware is available in Catalog Applications Firmware chapter.

Example JSON Message

{
"message": {
"version": 1,
"sequence": 1,
"timestamp": 1672910024
},
"attribute": {
"vendor_name": "HARDWARIO",
"product_name": "CHESTER-M",
"hw_variant": "CDGLS",
"hw_revision": "R3.2",
"fw_name": "CHESTER Push",
"fw_version": "v1.4.0",
"serial_number": "2159018247"
},
"system": {
"uptime": 173,
"voltage_rest": 3.96,
"voltage_load": 3.86,
"current_load": 38
},
"backup": {
"line_voltage": 0.01,
"batt_voltage": 3.43,
"state": "disconnected",
"events": [
{
"timestamp": 1672910010,
"type": "disconnected"
}
]
},
"network": {
"imei": 351358815178303,
"imsi": 901288003957939,
"parameter": {
"eest": 7,
"ecl": 0,
"rsrp": -87,
"rsrq": -6,
"snr": 13,
"plmn": 23003,
"cid": 939040,
"band": 20,
"earfcn": 6447
}
},
"thermometer": {
"temperature": 21.56
},
"accelerometer": {
"acceleration_x": -0.31,
"acceleration_y": 0.15,
"acceleration_z": 9.88,
"orientation": 2
},
"button_x": {
"count_click": 0,
"count_hold": 0,
"events": []
},
"button_1": {
"count_click": 3,
"count_hold": 1,
"events": [
{
"timestamp": 1672910020,
"type": "held"
}
]
},
"button_2": {
"count_click": 12,
"count_hold": 0,
"events": [
{
"timestamp": 1672910023,
"type": "clicked"
}
]
},
"button_3": {
"count_click": 0,
"count_hold": 0,
"events": []
},
"button_4": {
"count_click": 0,
"count_hold": 0,
"events": []
}
}